Open Type Diesel Generator Set

DHDL Open Type Diesel Generator Sets feature a steel base frame supporting the diesel engine, alternator, and control system. The generator range incorporates flexible or rigid engine-alternator connection arrangements, fuel tank configurations based on generator capacity, and sensor-based monitoring with protective alarm and shutdown functions. According to the supplied product information, generator sets below 500 kW use a base fuel tank, while units above 500 kW use a separate fuel tank, with both configurations described as supporting up to 8 hours of operation at rated load under specified conditions. These generator sets are suitable for industrial facilities, construction projects, infrastructure applications, and emergency backup power requirements.


Generator Type


Open Type Generator

Base Frame


Steel Frame Structure

Fuel Type


Diesel

Control System


Monitoring & Protection

Warranty 1 year

Product Overview

DHDL Open Type Diesel Generator Sets feature an open-frame structure with a steel base frame manufactured from bent steel plates or welded channel beams. Designed to provide structural strength and rigidity, the common base supports the diesel engine, alternator, and associated control equipment. The engine and alternator can be connected through flexible coupling or rigid connection arrangements, depending on the generator configuration.

The supplied product documentation describes different fuel tank arrangements according to generator capacity. Units below 500 kW use base-mounted fuel tanks, while units above 500 kW use separate fuel tanks. Both arrangements are described as supporting eight hours of operation at rated load under the stated design conditions. Actual fuel tank configuration and operating duration should be confirmed for the selected generator model.

Open type diesel generator sets incorporate operating sensors and a control system for equipment status monitoring and protection. Sensor information, including parameters such as engine coolant temperature, can be displayed through the control panel. When monitored values reach preset limits, the system can issue warning alarms and initiate automatic shutdown protection when required. Typical applications include manufacturing facilities, construction projects, municipal infrastructure, and emergency backup power systems.

Integrated Equipment

Generator Type Open Type Diesel Generator
Base Frame Steel Frame Structure
Main Components Diesel Engine, Alternator & Control System
Fuel Tank Arrangement Base Tank / Separate Tank
Protection System Monitoring, Alarm & Automatic Shutdown

General Technical Information

DHDL Open Type Diesel Generator Sets feature a steel base frame, integrated engine and alternator assemblies, fuel tank arrangements, and control systems designed for equipment monitoring and protection. The following information summarizes the structural and operating features described in the supplied product documentation.

Parameter Description
Product Name Open Type Diesel Generator Set
Generator Structure Open Type / Open Frame
Base Frame Bent Steel Plate or Welded Channel Beam Structure
Main Components Diesel Engine, Alternator, and Control System
Engine-Alternator Connection Flexible Coupling or Rigid Connection
Fuel Tank Arrangement Base-Mounted Fuel Tank for Units Below 500 kW; Separate Fuel Tank for Units Above 500 kW
Rated-Load Operating Duration 8 Hours (Stated in Product Documentation; Subject to Configuration)
Operating Monitoring Operating Sensors, Including Coolant Temperature Monitoring
Protection Functions Preset-Limit Warning Alarm and Automatic Shutdown Protection
Control Panel Arrangement Generator-Mounted Control Panel or Separate Control Panel
Control Panel Display Electrical Parameters and Engine Operating Parameters
Typical Applications Industrial Facilities, Emergency Backup Power, Construction Projects, Municipal Infrastructure, Telecommunications, and Mining Operations

Technical Note: The fuel tank arrangement for exactly 500 kW is not specified in the supplied product documentation. The stated 8-hour operating duration at rated load should be confirmed against the selected generator model, fuel tank capacity, and operating conditions. Rated power options, dimensions, generator weight, voltage, and frequency are not specified in the current documentation. Please contact DHDL for model-specific technical specifications.

Product Features

Robust Steel Base Frame

DHDL Open Type Diesel Generator Sets feature a steel base frame manufactured from bent steel plates or welded channel beams. This frame structure is designed to provide strength and rigidity while supporting the diesel engine, alternator, and associated equipment. The engine and alternator can be assembled using flexible coupling or rigid connection arrangements, depending on the selected generator configuration.

Fuel Tank Configurations

Different fuel tank arrangements are described according to generator capacity. Generator sets below 500 kW use base-mounted fuel tanks, while units above 500 kW use separate fuel tanks. The supplied documentation states an operating duration of eight hours at rated load for these arrangements. Actual tank configuration and runtime should be confirmed for each model.

Sensor-Based Protection

Operating sensors monitor generator conditions, including parameters such as engine coolant temperature. The control system receives sensor feedback and displays relevant operating information. When monitored values reach preset limits, warning alarms can be activated. The system can also initiate automatic shutdown protection when required to help protect the generator equipment.

Flexible Control Arrangements

The product documentation describes generator-mounted control panels and separate control panels installed in an operating room. Control panels connect with generator equipment and operating sensors through electrical cables to display electrical parameters and engine operating information. The suitable control panel arrangement depends on project and installation requirements.

Applications

DHDL Open Type Diesel Generator Sets provide power generation options for industrial facilities, emergency backup systems, and infrastructure projects. Featuring a steel base frame, integrated diesel engine and alternator assemblies, and sensor-based monitoring and protection systems, these generator sets can be considered for applications requiring an alternative electricity supply. Typical uses include emergency backup power, data centers, manufacturing plants, telecommunications facilities, construction projects, and mining operations. Generator selection should consider electrical load requirements, installation conditions, ventilation, and the intended operating environment.

Hospital emergency backup power application
Data center backup electricity supply application
Industrial manufacturing plant power supply application
Telecommunications infrastructure backup power application
Construction site temporary power supply application
Mining operations industrial diesel generator power application

    Get in Touch

    Send Your Transformer Inquiry


    Share your capacity, voltage, quantity, application, and destination country.
    Our engineering team will help confirm a suitable transformer or power distribution solution.

    Customized Solutions
    Technical Support
    Fast Response