COUNTRY-SPECIFIC TRANSFORMER SOLUTIONS · VIETNAM

Power Transformers for Vietnam’s Industrial & Distribution Projects

Explore transformer solutions for Vietnam’s 22kV and 35kV medium-voltage networks, manufacturing plants, industrial parks and utility substations. DHDL can review transformer designs against your project’s connection voltage, capacity, installation conditions and technical specifications.

22 / 35 kVMedium-voltage grid reference
110 kVDistribution-substation context
50 HzFréquence nominale de la grille
Illustrative oil-immersed transformer for industrial power distribution and substation applications

Illustrative product scene, not a photographed installation in Vietnam.

01 · CONTEXTE DU GRID LOCAL

Understanding Vietnam’s Power Grid & Industrial Supply

Vietnam’s electrical grid includes medium-voltage distribution feeders, 110kV substations and 220/500kV transmission networks. Industrial park projects frequently involve a 110kV substation feeding 22kV distribution, but the exact point of connection and supply arrangements are site-specific.

INDUSTRIAL DISTRIBUTION

22 kV Networks

Relevant to many industrial feeders, manufacturing loads and medium-voltage-to-low-voltage transformer projects.

Factories22kV feeders
ADDITIONAL DISTRIBUTION LEVELS

35 / 15 / 10 / 6 kV

Other nominal distribution levels remain in the regulatory voltage framework. Match the equipment to the actual local grid and connection documents.

Utility networksSite-specific
SUBSTATIONS & TRANSMISSION

110 / 220 / 500 kV

110kV is listed within the distribution system; 220kV and 500kV are transmission voltages. Higher-voltage equipment requires separate technical and manufacturing feasibility review.

SubstationsGrid interface

Vietnam nominal grid voltages are reference values—not a claim that every DHDL transformer model is available for each rating.

02 · RÉFÉRENCE DE TENSION

Vietnam Transformer Voltage & Specification Reference

Vietnam’s Circular 05/2025/TT-BCT lists nominal distribution voltages of 110, 35, 22, 15, 10, 6 and 0.38kV; transmission voltages are 220kV and 500kV. The following transformer ratios are illustrative engineering configurations, not universal national requirements.

Project contextGrid referenceÉvaluation des transformateursSpecify before ordering
Industrial LV supply22kV / low voltage22/0.4kV may be evaluated where the utility and load require itActual LV nominal voltage, winding ratio and tapping range
Other MV distribution35kV35kV-side distribution or industrial transformer optionsConnection drawings, insulation level and utility standards
Industrial park substation110kV / 22kVPower-transformer projects connecting a 110kV station to 22kV feedersCapacity, short-circuit impedance, vector group and protection
Existing regional distribution6 / 10 / 15kVSite-specific MV/LV or MV/MV transformersVerify the actual network voltage rather than assuming 22kV
Réseau de transmission220 / 500kVGrid context only; specialist power-transformer engineering reviewNo implied DHDL supply or certification commitment

Use the site’s single-line diagram, utility specification and latest applicable regulations as the governing documents.

03 · OPTIONS DE TRANSFORMATION

Transformer Options for Vietnam’s Project Requirements

Select the transformer construction after checking the required supply voltage, loading pattern, environment and installation space.

01

Oil-Immersed Distribution Transformers

For outdoor and utility-connected distribution applications, including project-specific medium-voltage-to-low-voltage supply.

Découvrez les transformateurs →
02

Transformateurs à type sec

For selected indoor factories, commercial buildings and industrial electrical rooms where dry-type construction meets project requirements.

Découvrez les transformateurs →
03

Transformateurs d'énergie des sous-stations

For industrial park substations and larger utility connections; voltage, MVA rating and feasibility are reviewed against project documents.

Débattre d'une spécification →
04 · GUIDE DE SELECTION

Choosing a Transformer for a Vietnam Project

01. Confirm Grid Connection

Request the utility-approved single-line diagram, primary and secondary nominal voltages, and operating frequency.

02. Define Load & Capacity

State the required kVA/MVA, continuous and peak load, motor starting requirements and expected plant expansion.

03. Check Climate & Installation

Consider tropical heat, humidity, ventilation, flood exposure and corrosion protection where relevant.

04. Coordinate Electrical Design

Confirm tap changer, vector group, impedance, earthing, insulation and protective-device coordination.

05. Agree Standards & Losses

Supply the project IEC/TCVN or utility requirements, efficiency targets, loss limits and acceptance-test plan.

06. Plan Delivery Documents

Clarify drawings, packing, test reports, certificates required by the tender, and the agreed delivery scope.

05 · APPLICATIONS DE PROJETS

Where Transformers Support Vietnam’s Industries

01 / MANUFACTURING

Factories & Industrial Parks

Electrical distribution for production lines, machinery, warehouses and industrial-park tenants with differing load needs.

02 / GRID CONNECTION

110/22kV Substations

Project-specific transformer selection at 110kV substations supplying 22kV distribution feeders.

03 / INFRASTRUCTURE

Infrastructure & Utility Upgrades

Transformers for distribution system reinforcement and facility power supply, subject to project specifications.

06 · Soutien au projet DHDL

Project-Based Manufacturing & Technical Review

DHDL offers transformer and power distribution equipment options for utility and industrial applications. For Vietnam projects, our first step is to review actual HV/LV voltages, load capacity, environmental conditions and relevant specification documents.

Any project-specific configuration, standards compliance, test scope and delivery requirements must be confirmed in the technical offer before purchase.

Découvrez la gamme de transformateurs →
Electrical specification reviewVoltage ratio, kVA/MVA, impedance, tapping and connection configuration
Application-focused design discussionOutdoor utility use, indoor factories and industrial substations
Inspection & testing coordinationAgree routine tests and technical documentation with the buyer
Export order preparationClarify packaging, documentation and delivery responsibilities
07 · QUESTIONS FREQUENTES

FAQ: Transformers for Vietnam

What is the common medium-voltage distribution level in Vietnam?

22kV is important for many distribution and industrial applications, but the national voltage framework also includes 35, 15, 10 and 6kV levels. Confirm the actual utility point of connection for each project.

Can a 22/0.4kV transformer be used for a Vietnam factory?

It can be considered when the approved incoming supply and required low-voltage output match those ratings. Final winding voltage, capacity, tap range and insulation requirements must be confirmed from project documents.

Is 110/22kV relevant for industrial parks?

Yes, documented industrial-park grid projects include 110kV substations with 22kV feeders. That does not mean every park has the same configuration.

What is Vietnam’s nominal grid frequency?

50Hz under the national electricity regulations. The supplied transformer specification and any project-specific requirements should still state frequency explicitly.

What technical information is needed for a quotation?

Share the single-line diagram, HV/LV winding voltages, capacity, quantity, frequency, vector group, impedance, installation conditions, applicable standards and required acceptance tests.

Can DHDL supply customized transformers for Vietnam?

DHDL can review custom technical requirements and propose suitable options where manufacturing capability and project specifications allow. Final feasibility and compliance are subject to confirmation.

08 · PROJET D’INTERROGATION

Need a Transformer for Your Vietnam Project?

Send your project location, HV/LV voltage ratio, capacity, quantity, installation conditions and electrical drawing. Our team can review the information and discuss an appropriate transformer solution.

Technical reference: Vietnam Ministry of Industry and Trade — Circular 05/2025/TT-BCT, Article 6; EVN — An Hoi 110kV substation and 22kV industrial-park feeders. Reference voltages are not final specifications or supply commitments.