{"id":38703,"date":"2026-09-14T10:45:28","date_gmt":"2026-09-14T10:45:28","guid":{"rendered":"https:\/\/dinghongtransformer.com\/?p=38703"},"modified":"2026-09-14T10:45:30","modified_gmt":"2026-09-14T10:45:30","slug":"transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation","status":"publish","type":"post","link":"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/","title":{"rendered":"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><a href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-what-engineers-should-check-before-failure-occurs\/\" data-type=\"post\" data-id=\"38598\" target=\"_blank\" rel=\"noreferrer noopener\">Transformer Oil<\/a>  is essential to the performance of an oil-immersed transformer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> It provides electrical insulation and helps transfer heat away from the transformer core and windings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, transformer oil can deteriorate because of moisture, contamination, oxidation, overheating, and electrical stress.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Regular transformer oil testing helps engineers monitor oil condition, establish a baseline, and identify potential problems before they develop into serious equipment failures.This guide explains what should be checked before commissioning and during transformer operation.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0421\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0438\u0442\u044c<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Why_Is_Transformer_Oil_Testing_Important\" >Why Is Transformer Oil Testing Important?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Transformer_Oil_Testing_Before_Commissioning\" >Transformer Oil Testing Before Commissioning<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Pre-Commissioning_Transformer_Oil_Checklist\" >Pre-Commissioning Transformer Oil Checklist<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#What_Should_Be_Checked_During_Transformer_Operation\" >What Should Be Checked During Transformer Operation?<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#1_Breakdown_Voltage\" >1. Breakdown Voltage<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#2_Moisture_Content\" >2. Moisture Content<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#3_Dissolved_Gas_Analysis_DGA\" >3. Dissolved Gas Analysis (DGA)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#4_Acidity_and_Oil_Aging\" >4. Acidity and Oil Aging<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#5_Dielectric_Dissipation_Factor\" >5. Dielectric Dissipation Factor<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#6_Visual_Inspection\" >6. Visual Inspection<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#When_Should_Transformer_Oil_Be_Tested\" >When Should Transformer Oil Be Tested?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Why_Trend_Analysis_Matters\" >Why Trend Analysis Matters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Transformer_Oil_Testing_and_Preventive_Maintenance\" >Transformer Oil Testing and Preventive Maintenance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#FAQ\" >FAQ<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#How_often_should_transformer_oil_be_tested\" >How often should transformer oil be tested?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#What_is_the_most_important_transformer_oil_test\" >What is the most important transformer oil test?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#What_can_transformer_oil_testing_detect\" >What can transformer oil testing detect?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Should_transformer_oil_be_tested_before_commissioning\" >Should transformer oil be tested before commissioning?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Can_transformer_oil_testing_prevent_transformer_failure\" >Can transformer oil testing prevent transformer failure?<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#Need_an_oil_immersed_transformer_for_Your_Project\" >Need an oil immersed transformer for Your Project?<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Is_Transformer_Oil_Testing_Important\"><\/span>Why Is Transformer Oil Testing Important?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The condition of transformer oil can provide valuable information about the condition of the transformer&#8217;s insulation system and internal components.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Regular oil testing can help:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Establish a baseline before commissioning<\/li>\n\n\n\n<li>Detect moisture and contamination<\/li>\n\n\n\n<li>Monitor oil aging and oxidation<\/li>\n\n\n\n<li>Identify possible thermal or electrical problems<\/li>\n\n\n\n<li>Track changes in transformer condition<\/li>\n\n\n\n<li>Support preventive maintenance<\/li>\n\n\n\n<li>Reduce the risk of unexpected downtime<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For this reason, oil testing should be part of a broader transformer maintenance and condition-monitoring program.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Transformer_Oil_Testing_Before_Commissioning\"><\/span>Transformer Oil Testing Before Commissioning<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Before a new oil-immersed transformer is energized, its oil condition should be checked according to the manufacturer&#8217;s recommendations, applicable standards, and project requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Pre-Commissioning_Transformer_Oil_Checklist\"><\/span>Pre-Commissioning Transformer Oil Checklist<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Test or Check<\/td><td>What It Evaluates<\/td><\/tr><tr><td>Appearance<\/td><td>Contamination, particles, cloudiness, or abnormal color<\/td><\/tr><tr><td>Breakdown voltage<\/td><td>Dielectric strength of the insulating oil<\/td><\/tr><tr><td>Moisture content<\/td><td>Water contamination and insulation condition<\/td><\/tr><tr><td>Acidity<\/td><td>Oil aging and oxidation<\/td><\/tr><tr><td>Dissipation factor<\/td><td>Dielectric losses and oil condition<\/td><\/tr><tr><td>Interfacial tension<\/td><td>Oil degradation and contamination<\/td><\/tr><tr><td>DGA, where required<\/td><td>Gases associated with thermal or electrical activity<\/td><\/tr><tr><td>Oil level<\/td><td>Correct operating oil level<\/td><\/tr><tr><td>Leakage inspection<\/td><td>Tank, valves, seals, radiators, and oil-containing components<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The results should be recorded as a baseline. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Future test results can then be compared with the initial condition to identify changes over time.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Should_Be_Checked_During_Transformer_Operation\"><\/span>What Should Be Checked During Transformer Operation?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Transformer oil should continue to be monitored after commissioning. The appropriate testing frequency depends on the transformer&#8217;s voltage, capacity, age, loading, operating environment, criticality, and maintenance program.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Breakdown_Voltage\"><\/span>1. Breakdown Voltage<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Breakdown voltage testing evaluates the ability of transformer oil to withstand electrical stress.A reduction may be associated with moisture, particles, or contamination.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> A significant change from previous results should be investigated.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Moisture_Content\"><\/span>2. Moisture Content<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Moisture can reduce the dielectric strength of transformer oil and affect the solid insulation inside the transformer.Water may enter through damaged seals, breathing-system problems, condensation, or poor storage and maintenance conditions.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Dissolved_Gas_Analysis_DGA\"><\/span>3. Dissolved Gas Analysis (DGA)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">DGA is an important diagnostic method for oil-filled transformers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thermal and electrical faults can generate gases that dissolve in transformer oil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Analyzing the type and concentration of these gases can provide clues about possible abnormal conditions.DGA results should be interpreted alongside historical data and other transformer test results.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Acidity_and_Oil_Aging\"><\/span>4. Acidity and Oil Aging<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Transformer oil can become more acidic as it ages and oxidizes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Monitoring acidity can help engineers evaluate oil deterioration and determine whether further investigation or maintenance is required.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Dielectric_Dissipation_Factor\"><\/span>5. Dielectric Dissipation Factor<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The dielectric dissipation factor, commonly known as tan delta, provides information about dielectric losses and the condition of insulating oil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Changes may indicate moisture, contamination, or deterioration and should be evaluated together with other test results.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Visual_Inspection\"><\/span>6. Visual Inspection<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">A visual inspection is a simple first step.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Unusual color, cloudiness, sediment, or visible particles may indicate that further laboratory testing is necessary.Visual appearance alone, however, should not be used to diagnose transformer condition.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"When_Should_Transformer_Oil_Be_Tested\"><\/span>When Should Transformer Oil Be Tested?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There is no single testing interval suitable for every transformer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> A maintenance program should consider the equipment&#8217;s operating conditions and manufacturer&#8217;s recommendations.<\/p>\n\n\n\n<div class=\"wp-block-wd-row wd-b0d85dc1\">\n<div class=\"wp-block-wd-column wd-95c7b742\">\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Situation<\/td><td>Recommended<\/td><\/tr><tr><td>Before commissioning<\/td><td>Establish baseline oil condition<\/td><\/tr><tr><td>After abnormal loading<\/td><td>Consider additional testing<\/td><\/tr><tr><td>After an electrical fault<\/td><td>Test oil and investigate transformer condition<\/td><\/tr><tr><td><\/td><td><\/td><\/tr><tr><td>After overheating<\/td><td>Consider additional diagnostic testing<\/td><\/tr><tr><td>After maintenance<\/td><td>Confirm oil condition before energization<\/td><\/tr><tr><td>Sudden change in results<\/td><td>Investigate promptly<\/td><\/tr><tr><td>Routine operation<\/td><td>Perform periodic oil analysis<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For critical transformers, more frequent monitoring may be appropriate.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Trend_Analysis_Matters\"><\/span>Why Trend Analysis Matters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A transformer may have acceptable oil-test results today but show deterioration later.Recording test results over time allows engineers to identify trends in moisture, acidity, dissolved gases, and dielectric properties.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For every test, record the transformer identification, test date, operating condition, sample information, results, previous results, and any recommended follow-up actions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This creates a useful history of transformer condition and supports more informed maintenance decisions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Transformer_Oil_Testing_and_Preventive_Maintenance\"><\/span>Transformer Oil Testing and Preventive Maintenance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Oil analysis should not be considered a replacement for complete transformer maintenance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Engineers should also monitor:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Oil and winding temperature<\/li>\n\n\n\n<li>Oil level<\/li>\n\n\n\n<li>Bushings<\/li>\n\n\n\n<li>Breathers<\/li>\n\n\n\n<li>Conservator system<\/li>\n\n\n\n<li>Cooling equipment<\/li>\n\n\n\n<li>Tank and gasket condition<\/li>\n\n\n\n<li>Protection devices<\/li>\n\n\n\n<li>Transformer loading<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Combining oil analysis with electrical testing and physical inspections provides a more complete view of transformer health.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_often_should_transformer_oil_be_tested\"><\/span>How often should transformer oil be tested?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The appropriate frequency depends on the transformer&#8217;s design, age, voltage, loading, environment, and criticality.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"> Baseline testing should be performed before commissioning, followed by periodic testing according to the maintenance program.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_the_most_important_transformer_oil_test\"><\/span>What is the most important transformer oil test?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">There is no single test that provides a complete diagnosis. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Breakdown voltage, moisture, DGA, acidity, and dielectric dissipation factor each provide different information and should be evaluated together.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_can_transformer_oil_testing_detect\"><\/span>What can transformer oil testing detect?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on the test, oil analysis can identify moisture, contamination, aging, oxidation, and gases associated with possible thermal or electrical problems.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Should_transformer_oil_be_tested_before_commissioning\"><\/span>Should transformer oil be tested before commissioning?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. Establishing baseline oil condition before energization provides a reference for future monitoring. Testing requirements should follow the applicable standards, project specifications, and manufacturer&#8217;s recommendations.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Can_transformer_oil_testing_prevent_transformer_failure\"><\/span>Can transformer oil testing prevent transformer failure?<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Testing cannot guarantee that a transformer will never fail. However, regular oil condition monitoring can help identify developing problems earlier and support preventive maintenance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Need_an_oil_immersed_transformer_for_Your_Project\"><\/span>Need an <a href=\"https:\/\/dinghongtransformer.com\/ru\/tag\/oil-immersed-transformer\/\" data-type=\"post_tag\" data-id=\"106\" target=\"_blank\" rel=\"noreferrer noopener\">oil immersed transformer<\/a> for Your Project?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choosing the right transformer starts with the correct technical specifications, insulation system, cooling arrangement, oil system, and operating requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/dinghongtransformer.com\/ru\/\" data-type=\"link\" data-id=\"https:\/\/dinghongtransformer.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">DinghongTransformer<\/a> provides customized oil-immersed transformers, power transformers, distribution transformers, and high-voltage transformer solutions for different power applications.Tell our engineering team your required voltage, capacity, application, quantity, cooling requirements, applicable standard, and project location.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contact <a href=\"https:\/\/DinghongTransformer.com\" data-type=\"link\" data-id=\"DinghongTransformer.com\" target=\"_blank\" rel=\"noreferrer noopener\">DinghongTransformer<\/a> today for expert transformer selection and a project-specific quotation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Transformer Oil is essential to the performance of an oil-immersed transformer. It provides electrical insulation and helps transfer heat away<\/p>","protected":false},"author":2,"featured_media":38706,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-38703","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation - Dinghongtransformer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation - Dinghongtransformer\" \/>\n<meta property=\"og:description\" content=\"Transformer Oil is essential to the performance of an oil-immersed transformer. It provides electrical insulation and helps transfer heat away\" \/>\n<meta property=\"og:url\" content=\"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/\" \/>\n<meta property=\"og:site_name\" content=\"Dinghongtransformer\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-14T10:45:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-14T10:45:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/09\/file_00000000a52881f5849bed3ba4caf1bd.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"941\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"kai xin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"kai xin\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 \u043c\u0438\u043d\u0443\u0442\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/\"},\"author\":{\"name\":\"kai xin\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/e63997f0c2f46d2ded1f6754c89005bb\"},\"headline\":\"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation\",\"datePublished\":\"2026-09-14T10:45:28+00:00\",\"dateModified\":\"2026-09-14T10:45:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/\"},\"wordCount\":1016,\"image\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/file_00000000a52881f5849bed3ba4caf1bd.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/\",\"name\":\"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation - Dinghongtransformer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/file_00000000a52881f5849bed3ba4caf1bd.png\",\"datePublished\":\"2026-09-14T10:45:28+00:00\",\"dateModified\":\"2026-09-14T10:45:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/e63997f0c2f46d2ded1f6754c89005bb\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/file_00000000a52881f5849bed3ba4caf1bd.png\",\"contentUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/file_00000000a52881f5849bed3ba4caf1bd.png\",\"width\":1672,\"height\":941},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/dinghongtransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/\",\"name\":\"Dinghongtransformer\",\"description\":\"DHDL manufactures transformers, high and low voltage distribution cabinets, prefabricated substations, energy storage cabinets and EV charging equipment for utility, industrial and new energy projects worldwide.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dinghongtransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/e63997f0c2f46d2ded1f6754c89005bb\",\"name\":\"kai xin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g\",\"caption\":\"kai xin\"},\"sameAs\":[\"https:\\\/\\\/dinghongtransformer.com\\\/\"],\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/ru\\\/author\\\/kaixin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation - Dinghongtransformer","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/","og_locale":"ru_RU","og_type":"article","og_title":"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation - Dinghongtransformer","og_description":"Transformer Oil is essential to the performance of an oil-immersed transformer. It provides electrical insulation and helps transfer heat away","og_url":"https:\/\/dinghongtransformer.com\/ru\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/","og_site_name":"Dinghongtransformer","article_published_time":"2026-09-14T10:45:28+00:00","article_modified_time":"2026-09-14T10:45:30+00:00","og_image":[{"width":1672,"height":941,"url":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/09\/file_00000000a52881f5849bed3ba4caf1bd.png","type":"image\/png"}],"author":"kai xin","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"kai xin","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"5 \u043c\u0438\u043d\u0443\u0442"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#article","isPartOf":{"@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/"},"author":{"name":"kai xin","@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/e63997f0c2f46d2ded1f6754c89005bb"},"headline":"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation","datePublished":"2026-09-14T10:45:28+00:00","dateModified":"2026-09-14T10:45:30+00:00","mainEntityOfPage":{"@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/"},"wordCount":1016,"image":{"@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#primaryimage"},"thumbnailUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/09\/file_00000000a52881f5849bed3ba4caf1bd.png","articleSection":["Blog"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/","url":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/","name":"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation - Dinghongtransformer","isPartOf":{"@id":"https:\/\/dinghongtransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#primaryimage"},"image":{"@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#primaryimage"},"thumbnailUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/09\/file_00000000a52881f5849bed3ba4caf1bd.png","datePublished":"2026-09-14T10:45:28+00:00","dateModified":"2026-09-14T10:45:30+00:00","author":{"@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/e63997f0c2f46d2ded1f6754c89005bb"},"breadcrumb":{"@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#primaryimage","url":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/09\/file_00000000a52881f5849bed3ba4caf1bd.png","contentUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/09\/file_00000000a52881f5849bed3ba4caf1bd.png","width":1672,"height":941},{"@type":"BreadcrumbList","@id":"https:\/\/dinghongtransformer.com\/blog\/transformer-oil-testing-checklist-what-to-check-before-commissioning-and-during-operation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/dinghongtransformer.com\/"},{"@type":"ListItem","position":2,"name":"Transformer Oil Testing Checklist: What to Check Before Commissioning and During Operation"}]},{"@type":"WebSite","@id":"https:\/\/dinghongtransformer.com\/#website","url":"https:\/\/dinghongtransformer.com\/","name":"Dinghongtransformer","description":"DHDL \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b, \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0448\u043a\u0430\u0444\u044b \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u0438 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438, \u0448\u043a\u0430\u0444\u044b \u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u043b\u044f \u0437\u0430\u0440\u044f\u0434\u043a\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u043e\u0431\u0438\u043b\u0435\u0439 \u0434\u043b\u044f \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445, \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0438 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u043f\u043e \u0432\u0441\u0435\u043c\u0443 \u043c\u0438\u0440\u0443.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dinghongtransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/e63997f0c2f46d2ded1f6754c89005bb","name":"kai xin","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g","caption":"kai xin"},"sameAs":["https:\/\/dinghongtransformer.com\/"],"url":"https:\/\/dinghongtransformer.com\/ru\/author\/kaixin\/"}]}},"_links":{"self":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts\/38703","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/comments?post=38703"}],"version-history":[{"count":1,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts\/38703\/revisions"}],"predecessor-version":[{"id":38704,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts\/38703\/revisions\/38704"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/media\/38706"}],"wp:attachment":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/media?parent=38703"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/categories?post=38703"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/tags?post=38703"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}