{"id":37738,"date":"2026-07-22T17:05:26","date_gmt":"2026-07-22T17:05:26","guid":{"rendered":"https:\/\/dinghongtransformer.com\/?p=37738"},"modified":"2026-08-12T03:47:10","modified_gmt":"2026-08-12T03:47:10","slug":"how-to-size-a-transformer-for-commercial-and-industrial-buildings","status":"publish","type":"post","link":"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/","title":{"rendered":"How to Size a Transformer for Commercial and Industrial Buildings"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Selecting the correct transformer size is one of the most important decisions in any commercial or industrial electrical project. An undersized transformer can lead to overheating, voltage drops, equipment failures, and costly downtime. On the other hand, an oversized transformer increases initial investment costs and can reduce overall energy efficiency.Whether you&#8217;re designing a new facility, expanding an existing operation, or replacing aging equipment, understanding how to properly size a transformer ensures reliable power distribution and long-term operational performance.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0421\u043e\u0434\u0435\u0440\u0436\u0430\u043d\u0438\u0435<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0438\u0442\u044c<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Why_Proper_Transformer_Sizing_Matters\" >Why Proper Transformer Sizing Matters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Step_1_Determine_the_Total_Connected_Load\" >Step 1: Determine the Total Connected Load<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Step_2_Calculate_the_Total_Demand_Load\" >Step 2: Calculate the Total Demand Load<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Step_3_Convert_kW_to_kVA\" >Step 3: Convert kW to kVA<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Step_4_Allow_for_Future_Expansion\" >Step 4: Allow for Future Expansion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Step_5_Consider_Starting_Currents\" >Step 5: Consider Starting Currents<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Step_6_Evaluate_Environmental_Conditions\" >Step 6: Evaluate Environmental Conditions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Common_Transformer_Sizing_Mistakes\" >Common Transformer Sizing Mistakes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#Partner_with_Dinghong_Transformer_for_Expert_Solutions\" >Partner with Dinghong Transformer for Expert Solutions<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Proper_Transformer_Sizing_Matters\"><\/span>Why Proper Transformer Sizing Matters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1200\" height=\"800\" data-src=\"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1-1200x800.png\" alt=\"\" class=\"wp-image-37748 lazyload\" data-srcset=\"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1-1200x800.png 1200w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1-400x267.png 400w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1-768x512.png 768w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1-430x287.png 430w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1-700x467.png 700w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1-150x100.png 150w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365651-1.png 1536w\" data-sizes=\"(max-width: 1200px) 100vw, 1200px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1200px; --smush-placeholder-aspect-ratio: 1200\/800;\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A transformer serves as the backbone of your electrical distribution system. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Choosing the right capacity helps to:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ensure stable voltage for connected equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prevent transformer overheating and premature failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Improve energy efficiency.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Reduce maintenance and operating costs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Support future expansion without frequent upgrades.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proper sizing is especially critical in industries where continuous power is essential, such as manufacturing plants, hospitals, commercial complexes, data centers, and renewable energy facilities.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_1_Determine_the_Total_Connected_Load\"><\/span>Step 1: Determine the Total Connected Load<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Begin by identifying all electrical equipment that will be powered by the transformer. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This includes:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lighting systems<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">HVAC equipment<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial machinery<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Motors<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Elevators<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Office equipment<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pumps and compressors<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Production lines<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Record the power rating of each load in kilowatts (kW) or kilovolt-amperes (kVA).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_2_Calculate_the_Total_Demand_Load\"><\/span>Step 2: Calculate the Total Demand Load<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Not every piece of equipment operates at full capacity simultaneously. Apply a demand factor based on the expected operating conditions to estimate the actual load.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Total connected load: 600 kW<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Demand factor: 80%<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Actual demand:600 \u00d7 0.8 = 480 kW<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Using demand load instead of connected load results in a more practical transformer selection.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_3_Convert_kW_to_kVA\"><\/span>Step 3: Convert kW to kVA<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Transformers are rated in kVA, not kW.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use the formula:kVA = kW \u00f7 Power Factor (PF)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Example:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Load = 480 kWPower Factor = 0.8480 \u00f7 0.8 = 600 kVA<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this case, a transformer with a rating of approximately 600 kVA would be required before considering additional safety margins.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_4_Allow_for_Future_Expansion\"><\/span>Step 4: Allow for Future Expansion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Commercial and industrial facilities often increase their electrical demand over time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When selecting a transformer, consider future additions such as:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">New production equipment<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Extra office space<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Additional HVAC systems<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EV charging stations<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Renewable energy integration<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Many engineers include a reserve capacity of approximately 15\u201325% to accommodate future growth without replacing the transformer.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_5_Consider_Starting_Currents\"><\/span>Step 5: Consider Starting Currents<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Large motors and compressors draw significantly higher current during startup.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your facility contains:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial motors<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compressors<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cranes<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pumps<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Heavy manufacturing equipment<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The transformer should be capable of handling these temporary inrush currents without excessive voltage drop.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Step_6_Evaluate_Environmental_Conditions\"><\/span>Step 6: Evaluate Environmental Conditions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Installation conditions also affect transformer selection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Consider factors such as:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Indoor or outdoor installation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ambient temperature<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ventilation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Humidity<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dust levels<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Corrosive environments<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Harsh environments may require specialized transformer designs or enhanced cooling systems to maintain reliable operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Common_Transformer_Sizing_Mistakes\"><\/span>Common Transformer Sizing Mistakes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Avoid these common errors when choosing a transformer:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1200\" height=\"800\" data-src=\"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662-1200x800.png\" alt=\"\" class=\"wp-image-37749 lazyload\" data-srcset=\"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662-1200x800.png 1200w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662-400x267.png 400w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662-768x512.png 768w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662-430x287.png 430w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662-700x467.png 700w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662-150x100.png 150w, https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/365662.png 1536w\" data-sizes=\"(max-width: 1200px) 100vw, 1200px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1200px; --smush-placeholder-aspect-ratio: 1200\/800;\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-wd-list wd-list wd-type-unordered wd-style-default wd-f271e442\">\n<li class=\"wp-block-wd-list-item wd-491bfca5\"><div class=\"wd-icon\"><\/div><span class=\"wd-list-content\">Selecting based only on current load without planning for expansion.<\/span><\/li>\n\n\n\n<li class=\"wp-block-wd-list-item wd-83325d15\"><div class=\"wd-icon\"><\/div><span class=\"wd-list-content\">Ignoring motor starting currents.<\/span><\/li>\n\n\n\n<li class=\"wp-block-wd-list-item wd-a749f9d4\"><div class=\"wd-icon\"><\/div><span class=\"wd-list-content\">Assuming all equipment operates simultaneously<\/span><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Partner_with_Dinghong_Transformer_for_Expert_Solutions\"><\/span>Partner with Dinghong Transformer for Expert Solutions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choosing the correct transformer involves more than calculating electrical load. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Application requirements, industry standards, environmental conditions, and future operational needs all play an important role in selecting the right solution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">At <a href=\"https:\/\/dinghongtransformer.com\/ru\/\">Dinghong Transformer<\/a>, we specialize in designing and manufacturing high-quality power and distribution transformers for commercial, industrial, utility, and renewable energy applications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Our experienced engineering team works closely with clients to recommend transformer solutions that match their voltage requirements, load capacity, installation environment, and long-term operational goals.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Whether you need an oil-immersed transformer, dry-type transformer, or a customized power distribution solution, Dinghong Transformer is committed to delivering reliable, energy-efficient products that meet international quality standards. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By partnering with <a href=\"https:\/\/dinghongtransformer.com\/ru\/\">Dinghong<\/a> you gain a trusted manufacturer focused on performance, durability, and long-term value for every project.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Learn how to size transformers for commercial and industrial buildings using demand load, power factor, expansion allowance and motor starting current.  <\/p>","protected":false},"author":2,"featured_media":37745,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-37738","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Size a Transformer for Commercial and Industrial Buildings - Dinghongtransformer<\/title>\n<meta name=\"description\" content=\"Learn how to size transformers for commercial and industrial buildings using demand load, power factor, expansion allowance and motor starting current.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Size a Transformer for Commercial and Industrial Buildings - Dinghongtransformer\" \/>\n<meta property=\"og:description\" content=\"Learn how to size transformers for commercial and industrial buildings using demand load, power factor, expansion allowance and motor starting current.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/\" \/>\n<meta property=\"og:site_name\" content=\"Dinghongtransformer\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-22T17:05:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-12T03:47:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/file_000000007aa481f48ec4181ceeb0f041.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"kai xin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"kai xin\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u043c\u0438\u043d\u0443\u0442\u044b\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/\"},\"author\":{\"name\":\"kai xin\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/e63997f0c2f46d2ded1f6754c89005bb\"},\"headline\":\"How to Size a Transformer for Commercial and Industrial Buildings\",\"datePublished\":\"2026-07-22T17:05:26+00:00\",\"dateModified\":\"2026-08-12T03:47:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/\"},\"wordCount\":613,\"image\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/file_000000007aa481f48ec4181ceeb0f041.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/\",\"name\":\"How to Size a Transformer for Commercial and Industrial Buildings - Dinghongtransformer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/file_000000007aa481f48ec4181ceeb0f041.png\",\"datePublished\":\"2026-07-22T17:05:26+00:00\",\"dateModified\":\"2026-08-12T03:47:10+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/e63997f0c2f46d2ded1f6754c89005bb\"},\"description\":\"Learn how to size transformers for commercial and industrial buildings using demand load, power factor, expansion allowance and motor starting current.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/#primaryimage\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/file_000000007aa481f48ec4181ceeb0f041.png\",\"contentUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/file_000000007aa481f48ec4181ceeb0f041.png\",\"width\":1536,\"height\":1024},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/dinghongtransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Size a Transformer for Commercial and Industrial Buildings\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/\",\"name\":\"Dinghongtransformer\",\"description\":\"DHDL manufactures transformers, high and low voltage distribution cabinets, prefabricated substations, energy storage cabinets and EV charging equipment for utility, industrial and new energy projects worldwide.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dinghongtransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/e63997f0c2f46d2ded1f6754c89005bb\",\"name\":\"kai xin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g\",\"caption\":\"kai xin\"},\"sameAs\":[\"https:\\\/\\\/dinghongtransformer.com\\\/\"],\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/ru\\\/author\\\/kaixin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Size a Transformer for Commercial and Industrial Buildings - Dinghongtransformer","description":"Learn how to size transformers for commercial and industrial buildings using demand load, power factor, expansion allowance and motor starting current.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/","og_locale":"ru_RU","og_type":"article","og_title":"How to Size a Transformer for Commercial and Industrial Buildings - Dinghongtransformer","og_description":"Learn how to size transformers for commercial and industrial buildings using demand load, power factor, expansion allowance and motor starting current.","og_url":"https:\/\/dinghongtransformer.com\/ru\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/","og_site_name":"Dinghongtransformer","article_published_time":"2026-07-22T17:05:26+00:00","article_modified_time":"2026-08-12T03:47:10+00:00","og_image":[{"width":1536,"height":1024,"url":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/file_000000007aa481f48ec4181ceeb0f041.png","type":"image\/png"}],"author":"kai xin","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"kai xin","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"4 \u043c\u0438\u043d\u0443\u0442\u044b"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#article","isPartOf":{"@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/"},"author":{"name":"kai xin","@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/e63997f0c2f46d2ded1f6754c89005bb"},"headline":"How to Size a Transformer for Commercial and Industrial Buildings","datePublished":"2026-07-22T17:05:26+00:00","dateModified":"2026-08-12T03:47:10+00:00","mainEntityOfPage":{"@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/"},"wordCount":613,"image":{"@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/file_000000007aa481f48ec4181ceeb0f041.png","articleSection":["Blog"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/","url":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/","name":"How to Size a Transformer for Commercial and Industrial Buildings - Dinghongtransformer","isPartOf":{"@id":"https:\/\/dinghongtransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#primaryimage"},"image":{"@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/file_000000007aa481f48ec4181ceeb0f041.png","datePublished":"2026-07-22T17:05:26+00:00","dateModified":"2026-08-12T03:47:10+00:00","author":{"@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/e63997f0c2f46d2ded1f6754c89005bb"},"description":"Learn how to size transformers for commercial and industrial buildings using demand load, power factor, expansion allowance and motor starting current.","breadcrumb":{"@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#primaryimage","url":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/file_000000007aa481f48ec4181ceeb0f041.png","contentUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/07\/file_000000007aa481f48ec4181ceeb0f041.png","width":1536,"height":1024},{"@type":"BreadcrumbList","@id":"https:\/\/dinghongtransformer.com\/blog\/how-to-size-a-transformer-for-commercial-and-industrial-buildings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/dinghongtransformer.com\/"},{"@type":"ListItem","position":2,"name":"How to Size a Transformer for Commercial and Industrial Buildings"}]},{"@type":"WebSite","@id":"https:\/\/dinghongtransformer.com\/#website","url":"https:\/\/dinghongtransformer.com\/","name":"Dinghongtransformer","description":"DHDL \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u044b, \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0448\u043a\u0430\u0444\u044b \u0432\u044b\u0441\u043e\u043a\u043e\u0433\u043e \u0438 \u043d\u0438\u0437\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f, \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442\u043d\u044b\u0435 \u0442\u0440\u0430\u043d\u0441\u0444\u043e\u0440\u043c\u0430\u0442\u043e\u0440\u043d\u044b\u0435 \u043f\u043e\u0434\u0441\u0442\u0430\u043d\u0446\u0438\u0438, \u0448\u043a\u0430\u0444\u044b \u043d\u0430\u043a\u043e\u043f\u0438\u0442\u0435\u043b\u0435\u0439 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u0438 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0434\u043b\u044f \u0437\u0430\u0440\u044f\u0434\u043a\u0438 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u043e\u0431\u0438\u043b\u0435\u0439 \u0434\u043b\u044f \u044d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445, \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0438 \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0432\u043e\u0437\u043e\u0431\u043d\u043e\u0432\u043b\u044f\u0435\u043c\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432 \u044d\u043d\u0435\u0440\u0433\u0438\u0438 \u043f\u043e \u0432\u0441\u0435\u043c\u0443 \u043c\u0438\u0440\u0443.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dinghongtransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/e63997f0c2f46d2ded1f6754c89005bb","name":"kai xin","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a505ff39ac3b707c24a6be2fbcc22075c0498732f5a9c687fcca08e66ea27711?s=96&d=mm&r=g","caption":"kai xin"},"sameAs":["https:\/\/dinghongtransformer.com\/"],"url":"https:\/\/dinghongtransformer.com\/ru\/author\/kaixin\/"}]}},"_links":{"self":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts\/37738","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/comments?post=37738"}],"version-history":[{"count":6,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts\/37738\/revisions"}],"predecessor-version":[{"id":38137,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/posts\/37738\/revisions\/38137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/media\/37745"}],"wp:attachment":[{"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/media?parent=37738"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/categories?post=37738"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dinghongtransformer.com\/ru\/wp-json\/wp\/v2\/tags?post=37738"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}