{"id":37965,"date":"2026-08-05T12:58:47","date_gmt":"2026-08-05T12:58:47","guid":{"rendered":"https:\/\/dinghongtransformer.com\/?p=37965"},"modified":"2026-08-05T13:08:48","modified_gmt":"2026-08-05T13:08:48","slug":"kyn28-metal-clad-withdrawable-switchgear-buyers-guide","status":"publish","type":"post","link":"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/","title":{"rendered":"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Medium-voltage switchgear sits between the incoming power source and the equipment that keeps a facility operating. Therefore, an incomplete specification can affect protection coordination, maintenance access, expansion plans, operating safety, and commissioning.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f77e86e8\">The <a href=\"https:\/\/dinghongtransformer.com\/es\/producto\/kyn28-metal-clad-withdrawable-switchgear\/\"><strong><em><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">DHDL KYN28 metal-clad withdrawable switchgear<\/mark><\/em><\/strong><\/a> is designed for 3.6\u201312kV three-phase AC power systems. It receives, distributes, controls, protects, and monitors electrical power in substations, power plants, industrial facilities, infrastructure projects, commercial buildings, data centers, renewable energy projects, and medium-voltage power rooms.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-973f2a63\">Moreover, the cabinet uses a metal-clad compartment structure with a withdrawable circuit breaker truck. This structure provides isolation between functional areas and allows operators to withdraw the circuit breaker for inspection, testing, maintenance, or replacement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6b53dc2b\">However, buyers should not select KYN28 switchgear by voltage alone. Instead, they should confirm the system current, short-circuit duty, single-line diagram, circuit breaker, protection relay, cable arrangement, cabinet layout, interlocking, communication, and applicable standard.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5a397644\">This guide explains how to make those decisions from the buyer\u2019s perspective.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice de contenidos<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Alternar tabla de contenidos\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Alternar<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#KYN28_Product_Overview\" >KYN28 Product Overview<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Why_Buyers_Choose_a_Withdrawable_Circuit_Breaker_Design\" >Why Buyers Choose a Withdrawable Circuit Breaker Design<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Easier_Inspection_and_Maintenance\" >Easier Inspection and Maintenance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#More_Practical_Breaker_Testing\" >More Practical Breaker Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Faster_Replacement_Planning\" >Faster Replacement Planning<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#How_the_Metal-Clad_Compartment_Structure_Helps_the_User\" >How the Metal-Clad Compartment Structure Helps the User<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Safety_Starts_with_the_Five-Prevention_Interlocking_System\" >Safety Starts with the Five-Prevention Interlocking System<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Electrical_Parameters_Buyers_Must_Confirm\" >Electrical Parameters Buyers Must Confirm<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Rated_Voltage\" >Rated Voltage<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Rated_Current\" >Rated Current<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Short-Circuit_Breaking_Capacity\" >Short-Circuit Breaking Capacity<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Main_Wiring_Scheme\" >Main Wiring Scheme<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Circuit_Breaker_Selection\" >Circuit Breaker Selection<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Protection_Relay_and_Communication_Requirements\" >Protection Relay and Communication Requirements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Current_Transformer_and_Voltage_Transformer_Data\" >Current Transformer and Voltage Transformer Data<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Cable_Entry_Exit_and_Termination\" >Cable Entry, Exit, and Termination<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Review_the_Cabinet_Drawing_Before_Production\" >Review the Cabinet Drawing Before Production<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#KYN28_Applications_from_the_Product_Page\" >KYN28 Applications from the Product Page<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Power_Plants\" >Power Plants<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Substations\" >Substations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Industrial_Distribution_Systems\" >Industrial Distribution Systems<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Infrastructure_Projects\" >Infrastructure Projects<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Commercial_Buildings_and_Data_Centers\" >Commercial Buildings and Data Centers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Renewable_Energy_Projects\" >Proyectos de energ\u00eda renovable<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Flexible_Configuration_and_Future_Expansion\" >Flexible Configuration and Future Expansion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Standards_and_Project_Documentation\" >Standards and Project Documentation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Factory_Inspection_and_Testing\" >Factory Inspection and Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Common_KYN28_Procurement_Mistakes\" >Common KYN28 Procurement Mistakes<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Asking_for_a_Price_Without_a_Single-Line_Diagram\" >Asking for a Price Without a Single-Line Diagram<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Providing_Voltage_but_Not_Fault_Level\" >Providing Voltage but Not Fault Level<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Selecting_a_Breaker_Brand_Without_Defining_Performance\" >Selecting a Breaker Brand Without Defining Performance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Ignoring_Cable_Dimensions\" >Ignoring Cable Dimensions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Treating_Five-Prevention_Interlocking_as_a_Marketing_Phrase\" >Treating Five-Prevention Interlocking as a Marketing Phrase<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Leaving_Future_Expansion_Undefined\" >Leaving Future Expansion Undefined<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-35\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Assuming_Every_Document_Comes_Standard\" >Assuming Every Document Comes Standard<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-36\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Information_to_Send_for_a_KYN28_Quotation\" >Information to Send for a KYN28 Quotation<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-37\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Required_Electrical_Information\" >Required Electrical Information<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-38\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Required_Circuit_Information\" >Required Circuit Information<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-39\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Required_Component_Information\" >Required Component Information<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-40\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Required_Installation_Information\" >Required Installation Information<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-41\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Required_Commercial_Information\" >Required Commercial Information<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-42\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Frequently_Asked_Questions\" >Frequently Asked Questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-43\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#What_voltage_range_does_DHDL_KYN28_switchgear_cover\" >What voltage range does DHDL KYN28 switchgear cover?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-44\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#What_does_KYN28_switchgear_do\" >What does KYN28 switchgear do?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-45\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Where_can_buyers_use_KYN28_switchgear\" >Where can buyers use KYN28 switchgear?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-46\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Why_does_KYN28_use_a_withdrawable_circuit_breaker\" >Why does KYN28 use a withdrawable circuit breaker?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-47\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#What_is_the_difference_between_KYN28_and_an_RMU\" >What is the difference between KYN28 and an RMU?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-48\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Does_KYN28_include_five-prevention_interlocking\" >Does KYN28 include five-prevention interlocking?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-49\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Can_DHDL_customize_KYN28_switchgear\" >Can DHDL customize KYN28 switchgear?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-50\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Which_standards_does_the_product_follow\" >Which standards does the product follow?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-51\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#What_information_does_DHDL_need_for_a_quotation\" >What information does DHDL need for a quotation?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-52\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#Choose_KYN28_Around_the_Complete_Power_System\" >Choose KYN28 Around the Complete Power System<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-wd-title title wd-34e49c85\"><span class=\"ez-toc-section\" id=\"KYN28_Product_Overview\"><\/span>KYN28 Product Overview<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-99c37c21\">DHDL publishes the following product information:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Product item<\/th><th>DHDL specification<\/th><\/tr><tr><td>Product type<\/td><td>KYN28 metal-clad withdrawable switchgear<\/td><\/tr><tr><td>Voltage range<\/td><td>3.6\u201312kV<\/td><\/tr><tr><td>System type<\/td><td>Three-phase AC medium-voltage power system<\/td><\/tr><tr><td>Cabinet structure<\/td><td>Metal-clad compartment structure with withdrawable circuit breaker truck<\/td><\/tr><tr><td>Main functions<\/td><td>Power distribution, control, protection, and monitoring<\/td><\/tr><tr><td>Applications<\/td><td>Power plants, substations, industrial distribution systems, infrastructure projects, commercial buildings, data centers, renewable energy projects, and medium-voltage power rooms<\/td><\/tr><tr><td>Customizable items<\/td><td>Voltage level, rated current, circuit configuration, breaker type, protection relay, cabinet layout, and applicable standards<\/td><\/tr><tr><td>Additional project customization<\/td><td>Breaking capacity, main wiring scheme, circuit breaker brand, protection device, and communication system<\/td><\/tr><tr><td>Published standards<\/td><td>IEC 62271 and GB\/T 3906<\/td><\/tr><tr><td>Published warranty<\/td><td>One year<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a40f5099\">Although this information defines the product family, the final configuration remains project-specific. Consequently, DHDL needs the electrical data and single-line diagram before it can confirm the technical solution.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-a866f5ba\"><span class=\"ez-toc-section\" id=\"Why_Buyers_Choose_a_Withdrawable_Circuit_Breaker_Design\"><\/span>Why Buyers Choose a Withdrawable Circuit Breaker Design<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a6d707a7\">The circuit breaker represents a critical switching and protection component inside the cabinet. In KYN28 switchgear, DHDL places the breaker on a withdrawable truck.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-27e7ebe8\">As a result, operators can move the breaker between its defined positions and withdraw it for inspection, testing, maintenance, or replacement without complex cabinet disassembly.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-8a401eeb\"><span class=\"ez-toc-section\" id=\"Easier_Inspection_and_Maintenance\"><\/span>Easier Inspection and Maintenance<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-54482851\">A withdrawable breaker can simplify access to the breaker itself. Therefore, maintenance teams can inspect or service the unit outside its normal operating position.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d3c48536\">Nevertheless, withdrawability does not mean that personnel can ignore isolation procedures. Operators must still follow the approved operating sequence, interlocking logic, safety rules, and site procedures.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-c17cc40f\"><span class=\"ez-toc-section\" id=\"More_Practical_Breaker_Testing\"><\/span>More Practical Breaker Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-97a005cb\">The withdrawable arrangement supports defined service and test positions, depending on the final design.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-80d9c405\">Consequently, commissioning and maintenance teams can verify control, indication, and protection functions under the approved operating procedure.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1209e842\">Before ordering, buyers should confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Service position<\/li>\n\n\n\n<li>Test position<\/li>\n\n\n\n<li>Isolated position<\/li>\n\n\n\n<li>Breaker racking method<\/li>\n\n\n\n<li>Position indication<\/li>\n\n\n\n<li>Secondary plug arrangement<\/li>\n\n\n\n<li>Mechanical interlocking<\/li>\n\n\n\n<li>Electrical interlocking<\/li>\n\n\n\n<li>Shutter operation<\/li>\n\n\n\n<li>Breaker interchangeability requirements<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d7090695\"><span class=\"ez-toc-section\" id=\"Faster_Replacement_Planning\"><\/span>Faster Replacement Planning<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-42077fc5\">If a project keeps a compatible spare breaker, the withdrawable design can support a more practical replacement strategy.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bcd2e454\">However, the buyer must define what \u201cinterchangeable\u201d means in the project. Breaker rating, control voltage, auxiliary contacts, secondary plug, mechanism, protection interfaces, and physical arrangement must all match.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d1c041a5\">Therefore, do not assume that two breakers are interchangeable only because they fit KYN28 cabinets.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-a6c346e0\"><span class=\"ez-toc-section\" id=\"How_the_Metal-Clad_Compartment_Structure_Helps_the_User\"><\/span>How the Metal-Clad Compartment Structure Helps the User<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3a8c0724\">DHDL describes the KYN28 cabinet as a metal-clad compartment structure.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8971b1f7\">In practical terms, the cabinet divides key functions into separate areas. Depending on the approved configuration, these areas may include the circuit breaker, busbar, cable connection, and low-voltage control functions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6413d22c\">This separation can help the project team organize operation, maintenance, and fault management. Moreover, it supports a structured equipment layout within the switchgear lineup.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ebed0ca5\">Nevertheless, the buyer should verify the exact compartment arrangement on the project drawing rather than relying on a general product description.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1a1f28ac\">Ask DHDL to identify:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Circuit breaker compartment<\/li>\n\n\n\n<li>Busbar compartment<\/li>\n\n\n\n<li>Cable compartment<\/li>\n\n\n\n<li>Low-voltage control compartment<\/li>\n\n\n\n<li>Pressure-relief arrangement<\/li>\n\n\n\n<li>Internal shutters<\/li>\n\n\n\n<li>Earthing points<\/li>\n\n\n\n<li>Inspection windows<\/li>\n\n\n\n<li>Cable-entry direction<\/li>\n\n\n\n<li>Access requirements<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-37a7a0cc\"><span class=\"ez-toc-section\" id=\"Safety_Starts_with_the_Five-Prevention_Interlocking_System\"><\/span>Safety Starts with the Five-Prevention Interlocking System<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eda51b46\">DHDL states that the KYN28 switchgear includes a complete five-prevention interlocking system.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-48fbc953\">The system helps reduce the risk of incorrect opening or closing, load-switching errors, live earthing, and accidental entry into energized compartments.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4e72b2fb\">For buyers, however, the phrase \u201cfive-prevention\u201d should lead to a documented interlocking matrix.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2abbf775\">Therefore, request written confirmation of how the cabinet prevents unsafe operating sequences.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Interlocking review item<\/td><td>Buyer-side question<\/td><\/tr><tr><td>Circuit breaker operation<\/td><td>Under which conditions can the breaker open or close?<\/td><\/tr><tr><td>Breaker movement<\/td><td>Can personnel move the breaker truck while the breaker remains closed?<\/td><\/tr><tr><td>Earthing switch<\/td><td>What conditions allow the earthing switch to operate?<\/td><\/tr><tr><td>Cable compartment access<\/td><td>What prevents access when the relevant circuit remains energized?<\/td><\/tr><tr><td>Shutter system<\/td><td>How do the shutters cover energized primary contacts?<\/td><\/tr><tr><td>Breaker position<\/td><td>How does the system indicate service, test, and isolated positions?<\/td><\/tr><tr><td>Key interlocking<\/td><td>Does the project require coordination with upstream or downstream equipment?<\/td><\/tr><tr><td>Electrical interlocking<\/td><td>Which external permissive or blocking signals does the cabinet require?<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ba355aed\">The five-prevention system can support safer operation. Nevertheless, operators still need approved procedures, training, labeling, maintenance, and site-specific risk controls.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-9e8de83f\"><\/h2>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-176baef1\"><span class=\"ez-toc-section\" id=\"Electrical_Parameters_Buyers_Must_Confirm\"><\/span>Electrical Parameters Buyers Must Confirm<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fcd91aa0\">DHDL confirms a voltage range of 3.6\u201312kV. However, that range alone does not define a complete switchgear specification.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-7d35775c\"><span class=\"ez-toc-section\" id=\"Rated_Voltage\"><\/span>Rated Voltage<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-09adfa23\">Select the switchgear voltage class according to the power system and applicable standard.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-df50ed01\">Provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nominal system voltage<\/li>\n\n\n\n<li>Highest voltage for equipment<\/li>\n\n\n\n<li>Frecuencia<\/li>\n\n\n\n<li>Earthing method<\/li>\n\n\n\n<li>Insulation requirements<\/li>\n\n\n\n<li>Operating voltage variation<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-3a9425ed\"><span class=\"ez-toc-section\" id=\"Rated_Current\"><\/span>Rated Current<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6c6dfd8b\">The main busbar and each feeder must carry the required continuous current.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c057965d\">Therefore, provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Incoming feeder current<\/li>\n\n\n\n<li>Outgoing feeder current<\/li>\n\n\n\n<li>Transformer feeder current<\/li>\n\n\n\n<li>Bus coupler current<\/li>\n\n\n\n<li>Future load<\/li>\n\n\n\n<li>Ambient temperature<\/li>\n\n\n\n<li>Diversity assumptions<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c18bad48\">Do not select every feeder from the total busbar current. Instead, define the actual duty of each circuit.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-15f463a6\"><span class=\"ez-toc-section\" id=\"Short-Circuit_Breaking_Capacity\"><\/span>Short-Circuit Breaking Capacity<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-467a9939\">The circuit breaker must match the system fault level.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a5efb712\">Consequently, provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Calculated short-circuit current<\/li>\n\n\n\n<li>Required breaking capacity<\/li>\n\n\n\n<li>Required making capacity<\/li>\n\n\n\n<li>Short-time withstand current<\/li>\n\n\n\n<li>Short-circuit duration<\/li>\n\n\n\n<li>Protection clearing time<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d476e6cf\">DHDL can customize the breaking capacity according to the project. Nevertheless, the buyer remains responsible for providing accurate network data.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d7e12a9a\"><span class=\"ez-toc-section\" id=\"Main_Wiring_Scheme\"><\/span>Main Wiring Scheme<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-18cdf84a\">The single-line diagram defines how the switchgear must function.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-005e1d07\">It should show:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Incoming feeders<\/li>\n\n\n\n<li>Outgoing feeders<\/li>\n\n\n\n<li>Transformer feeders<\/li>\n\n\n\n<li>Bus sections<\/li>\n\n\n\n<li>Bus coupler<\/li>\n\n\n\n<li>Metering<\/li>\n\n\n\n<li>Earthing<\/li>\n\n\n\n<li>Station service<\/li>\n\n\n\n<li>Future panels<\/li>\n\n\n\n<li>Protection zones<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-05006468\">Without this diagram, suppliers may quote different equipment scopes. Therefore, always issue the latest approved revision with the RFQ.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-794dd5a0\"><span class=\"ez-toc-section\" id=\"Circuit_Breaker_Selection\"><\/span>Circuit Breaker Selection<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a703ec14\">DHDL can customize the breaker type and circuit breaker brand.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b081b257\">However, buyers should define the required performance instead of selecting a brand name alone.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fa454f63\">Confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Rated voltage<\/li>\n\n\n\n<li>Rated current<\/li>\n\n\n\n<li>Breaking capacity<\/li>\n\n\n\n<li>Making capacity<\/li>\n\n\n\n<li>Operating sequence<\/li>\n\n\n\n<li>Mechanical endurance<\/li>\n\n\n\n<li>Electrical endurance<\/li>\n\n\n\n<li>Spring-charged or other approved operating mechanism<\/li>\n\n\n\n<li>Trip coil voltage<\/li>\n\n\n\n<li>Closing coil voltage<\/li>\n\n\n\n<li>Motor voltage<\/li>\n\n\n\n<li>Auxiliary contacts<\/li>\n\n\n\n<li>Anti-pumping function<\/li>\n\n\n\n<li>Position indication<\/li>\n\n\n\n<li>Interchangeability<\/li>\n\n\n\n<li>Spare-parts availability<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fa749579\">Moreover, confirm whether the breaker supplier can support the destination market during the expected operating life.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-c720d357\"><span class=\"ez-toc-section\" id=\"Protection_Relay_and_Communication_Requirements\"><\/span>Protection Relay and Communication Requirements<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-21bbebb9\">DHDL also lists protection relays and communication systems among the customizable items.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-45ee144c\">Therefore, the buyer should provide a protection philosophy rather than a general request for \u201cdigital protection.\u201d<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-059db96e\">Depending on the circuit, the project may require:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Overcurrent protection<\/li>\n\n\n\n<li>Earth-fault protection<\/li>\n\n\n\n<li>Transformer protection<\/li>\n\n\n\n<li>Motor protection<\/li>\n\n\n\n<li>Feeder protection<\/li>\n\n\n\n<li>Bus protection interfaces<\/li>\n\n\n\n<li>Under-voltage or over-voltage functions<\/li>\n\n\n\n<li>Frequency protection<\/li>\n\n\n\n<li>Arc-related protection where specified<\/li>\n\n\n\n<li>Metering<\/li>\n\n\n\n<li>Event recording<\/li>\n\n\n\n<li>Disturbance recording<\/li>\n\n\n\n<li>Communication with SCADA<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-14e3a6ab\">In addition, confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Relay brand or approved vendor list<\/li>\n\n\n\n<li>Communication protocol<\/li>\n\n\n\n<li>Time synchronization<\/li>\n\n\n\n<li>Digital and analog point list<\/li>\n\n\n\n<li>Remote opening and closing<\/li>\n\n\n\n<li>Local and remote selector logic<\/li>\n\n\n\n<li>Cybersecurity requirements<\/li>\n\n\n\n<li>Language<\/li>\n\n\n\n<li>Setting-file responsibility<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8d24698e\">The relay does not work independently from the current transformers, voltage transformers, trip circuit, and communication system. Consequently, review the entire protection chain.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-28b97793\"><span class=\"ez-toc-section\" id=\"Current_Transformer_and_Voltage_Transformer_Data\"><\/span>Current Transformer and Voltage Transformer Data<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ae9d814f\">Instrument-transformer requirements can vary between metering and protection functions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-90e32a61\">Therefore, provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ratio<\/li>\n\n\n\n<li>Number of cores<\/li>\n\n\n\n<li>Accuracy class<\/li>\n\n\n\n<li>Protection class<\/li>\n\n\n\n<li>Burden<\/li>\n\n\n\n<li>Accuracy limit factor where required<\/li>\n\n\n\n<li>Metering requirements<\/li>\n\n\n\n<li>Utility approval requirements<\/li>\n\n\n\n<li>Secondary earthing<\/li>\n\n\n\n<li>Test-terminal requirements<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9f64b971\">If the buyer leaves these details undefined, the proposed switchgear may not support the final relay and metering design.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2214b02c\"><span class=\"ez-toc-section\" id=\"Cable_Entry_Exit_and_Termination\"><\/span>Cable Entry, Exit, and Termination<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-65a42731\">DHDL specifically asks buyers to provide the cable entry and exit method when requesting a quotation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5a916fbc\">This information affects the cabinet layout, cable compartment, supports, termination space, and installation plan.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b4895707\">Confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bottom, top, rear, or project-specific cable entry<\/li>\n\n\n\n<li>Number of cables per phase<\/li>\n\n\n\n<li>Cable conductor size<\/li>\n\n\n\n<li>Cable insulation type<\/li>\n\n\n\n<li>Cable outside diameter<\/li>\n\n\n\n<li>Termination type<\/li>\n\n\n\n<li>Cable bending radius<\/li>\n\n\n\n<li>Surge arrester requirement<\/li>\n\n\n\n<li>Current transformer position<\/li>\n\n\n\n<li>Earthing cable<\/li>\n\n\n\n<li>Cable basement depth<\/li>\n\n\n\n<li>Required installation access<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-35224757\">Moreover, check whether the cable contractor can install and test the terminations within the available compartment space.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-6d5a4d69\"><span class=\"ez-toc-section\" id=\"Review_the_Cabinet_Drawing_Before_Production\"><\/span>Review the Cabinet Drawing Before Production<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-693ce8f8\">The standard product image shows the appearance of a KYN28 cabinet. However, it does not replace an order-specific drawing.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1876d28b\">Image caption:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a1406034\">DHDL KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV medium-voltage power systems.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4e218cf6\">Before production, ask DHDL to provide the lineup and cabinet drawings.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Drawing item<\/td><td>Buyer-side verification<\/td><\/tr><tr><td>Total lineup length<\/td><td>Confirm that the complete switchgear fits the power room<\/td><\/tr><tr><td>Cabinet width<\/td><td>Check wall, column, and future-extension clearances<\/td><\/tr><tr><td>Cabinet height<\/td><td>Confirm ceiling, ventilation, and lifting clearance<\/td><\/tr><tr><td>Cabinet depth<\/td><td>Reserve front and rear access where required<\/td><\/tr><tr><td>Door opening<\/td><td>Verify safe operating and maintenance space<\/td><\/tr><tr><td>Cable compartment<\/td><td>Confirm cable quantity, bending radius, and termination access<\/td><\/tr><tr><td>Busbar position<\/td><td>Coordinate panel assembly and future extension<\/td><\/tr><tr><td>Pressure-relief direction<\/td><td>Keep the designated path clear<\/td><\/tr><tr><td>Foundation channels<\/td><td>Coordinate the civil design<\/td><\/tr><tr><td>Cable trench<\/td><td>Check position, width, and depth<\/td><\/tr><tr><td>Secondary cable entry<\/td><td>Coordinate protection, control, and SCADA wiring<\/td><\/tr><tr><td>Panel numbering<\/td><td>Match the single-line diagram<\/td><\/tr><tr><td>Shipping sections<\/td><td>Confirm door, truck, container, crane, and site access<\/td><\/tr><tr><td>Future panels<\/td><td>Reserve space and confirm extension interfaces<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ac332d0d\">Furthermore, coordinate the drawing with the civil, electrical, protection, cable, and installation teams.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-800ad398\"><span class=\"ez-toc-section\" id=\"KYN28_Applications_from_the_Product_Page\"><\/span>KYN28 Applications from the Product Page<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e865ab51\">DHDL identifies several applications for KYN28 switchgear.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-689746b7\"><span class=\"ez-toc-section\" id=\"Power_Plants\"><\/span>Power Plants<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5ac4ee1d\">KYN28 can support medium-voltage power distribution, control, protection, and monitoring within power plant systems.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ddf7d0e2\">However, the project must define generator auxiliary loads, transformer feeders, motor duty, fault level, and operating sequence.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bc0898e0\"><span class=\"ez-toc-section\" id=\"Substations\"><\/span>Substations<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5e805e82\">In substations, KYN28 can form part of the medium-voltage incoming, bus, transformer, and outgoing feeder arrangement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d8d1b2cd\">Where the project also requires transformers, buyers can coordinate the switchgear with DHDL\u2019s <a href=\"https:\/\/dinghongtransformer.com\/es\/producto\/6-37kv-dry-type-distribution-transformer\/\"><strong><em><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">6\u201337kV dry-type distribution transformer<\/mark><\/em><\/strong><\/a> or <strong><em><a href=\"https:\/\/dinghongtransformer.com\/es\/producto\/6-38-5kv-oil-immersed-distribution-transformer\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">6\u201338.5kV oil-immersed distribution transformer<\/mark><\/a><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">,<\/mark><\/em><\/strong> depending on the installation and project requirements.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e1ba5f42\">These transformer links do not imply automatic compatibility. Therefore, confirm voltage ratio, rated current, fault level, protection, cable interfaces, and installation environment.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-d7ea6f29\"><span class=\"ez-toc-section\" id=\"Industrial_Distribution_Systems\"><\/span>Industrial Distribution Systems<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dcdca9b8\">Factories, workshops, production lines, mining facilities, and industrial power systems may use KYN28 switchgear for medium-voltage control and protection.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0b4970dc\">In these projects, buyers should pay particular attention to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Large motors<\/li>\n\n\n\n<li>Motor-starting current<\/li>\n\n\n\n<li>Transformer inrush<\/li>\n\n\n\n<li>Frequent switching<\/li>\n\n\n\n<li>Process shutdown cost<\/li>\n\n\n\n<li>Maintenance windows<\/li>\n\n\n\n<li>Spare breaker strategy<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-2ed8c544\"><span class=\"ez-toc-section\" id=\"Infrastructure_Projects\"><\/span>Infrastructure Projects<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-13441b0c\">KYN28 can also support infrastructure power rooms.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-21992a8a\">However, infrastructure projects may require specific documentation, redundancy, fire-safety coordination, remote monitoring, and phased commissioning.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-3e33a1ee\"><span class=\"ez-toc-section\" id=\"Commercial_Buildings_and_Data_Centers\"><\/span>Commercial Buildings and Data Centers<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0f8e3656\">DHDL includes commercial buildings and data centers among the product applications.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-829a0c1a\">Because these sites can place a high value on continuity, buyers should define:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Redundant incomers<\/li>\n\n\n\n<li>Bus coupler logic<\/li>\n\n\n\n<li>Automatic transfer requirements<\/li>\n\n\n\n<li>Selective protection<\/li>\n\n\n\n<li>Remote monitoring<\/li>\n\n\n\n<li>Planned maintenance strategy<\/li>\n\n\n\n<li>Future capacity<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-fb7a3073\"><span class=\"ez-toc-section\" id=\"Renewable_Energy_Projects\"><\/span>Proyectos de energ\u00eda renovable<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6aa4d46a\">Solar, wind, energy storage, and microgrid projects may use medium-voltage switchgear for incoming, outgoing, transformer, and grid-connection circuits.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-350bcd2d\">Nevertheless, the project must confirm power-flow direction, operating cycles, protection coordination, grid requirements, and communication interfaces.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-42c1e928\"><span class=\"ez-toc-section\" id=\"Flexible_Configuration_and_Future_Expansion\"><\/span>Flexible Configuration and Future Expansion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c0d8ca86\">DHDL states that the modular cabinet design supports flexible circuit combinations, layout adjustment, and future expansion.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c270e60f\">Therefore, buyers should define realistic expansion needs during the initial design.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8a3811d2\">Confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Number of future panels<\/li>\n\n\n\n<li>Expansion direction<\/li>\n\n\n\n<li>Future busbar rating<\/li>\n\n\n\n<li>Prepared busbar interface<\/li>\n\n\n\n<li>Building space<\/li>\n\n\n\n<li>Cable trench extension<\/li>\n\n\n\n<li>Protection and communication capacity<\/li>\n\n\n\n<li>Auxiliary power capacity<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a8b31c9d\">A statement such as \u201callow for future expansion\u201d remains too vague. Instead, specify the expected circuits and ratings.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-edbc315e\"><span class=\"ez-toc-section\" id=\"Standards_and_Project_Documentation\"><\/span>Standards and Project Documentation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9e9898db\">DHDL states that KYN28 switchgear follows IEC 62271, GB\/T 3906, and other applicable international or domestic standards.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-97062e1b\">Moreover, DHDL states that it can provide type-test reports and relevant certification documents according to project requirements.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f6ddd5d9\">However, buyers should confirm the exact standard edition, product scope, rated parameters, and document availability before ordering.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2fd6c5a8\">Request:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Applicable standard list<\/li>\n\n\n\n<li>Technical data sheet<\/li>\n\n\n\n<li>Type-test report<\/li>\n\n\n\n<li>Routine-test procedure<\/li>\n\n\n\n<li>Routine-test report<\/li>\n\n\n\n<li>General arrangement drawing<\/li>\n\n\n\n<li>Single-line diagram<\/li>\n\n\n\n<li>Schematic drawings<\/li>\n\n\n\n<li>Wiring diagrams<\/li>\n\n\n\n<li>Terminal plan<\/li>\n\n\n\n<li>Interlocking matrix<\/li>\n\n\n\n<li>Component list<\/li>\n\n\n\n<li>Nameplate drawing<\/li>\n\n\n\n<li>Installation manual<\/li>\n\n\n\n<li>Operation manual<\/li>\n\n\n\n<li>Maintenance manual<\/li>\n\n\n\n<li>Packing list<\/li>\n\n\n\n<li>Spare-parts list<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cce36fbf\">Do not assume that a general report covers every customized configuration.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-2aad90ce\"><span class=\"ez-toc-section\" id=\"Factory_Inspection_and_Testing\"><\/span>Factory Inspection and Testing<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-59c176ec\">The KYN28 page does not publish a complete model-specific routine-test table. Therefore, the contract should define the required inspection and test plan.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8699533b\">The project may need to confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Visual and dimensional inspection<\/li>\n\n\n\n<li>Component verification<\/li>\n\n\n\n<li>Mechanical operation<\/li>\n\n\n\n<li>Circuit breaker racking<\/li>\n\n\n\n<li>Interlocking<\/li>\n\n\n\n<li>Main-circuit resistance<\/li>\n\n\n\n<li>Insulation testing<\/li>\n\n\n\n<li>Power-frequency withstand testing<\/li>\n\n\n\n<li>Control and auxiliary circuits<\/li>\n\n\n\n<li>Protection relay functions<\/li>\n\n\n\n<li>Metering<\/li>\n\n\n\n<li>Alarm and indication<\/li>\n\n\n\n<li>Communication<\/li>\n\n\n\n<li>Wiring continuity<\/li>\n\n\n\n<li>Phase sequence<\/li>\n\n\n\n<li>Nameplate<\/li>\n\n\n\n<li>Packing inspection<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-79f49432\">The exact test scope must follow the approved standard and project agreement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d959837d\">DHDL\u2019s <a href=\"https:\/\/dinghongtransformer.com\/es\/manufacture-capability\/\"><strong><em><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">manufacturing capability<\/mark><\/em><\/strong><\/a> page describes switchgear installation, complete-equipment integration, material inspection, assembly control, final inspection, technical documentation, and export packing.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b9da3dd0\">Therefore, buyers should convert these general capabilities into order-specific witness points and deliverables.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-72716083\"><span class=\"ez-toc-section\" id=\"Common_KYN28_Procurement_Mistakes\"><\/span>Common KYN28 Procurement Mistakes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-9e3e249d\"><span class=\"ez-toc-section\" id=\"Asking_for_a_Price_Without_a_Single-Line_Diagram\"><\/span>Asking for a Price Without a Single-Line Diagram<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b35d61e1\">Without the single-line diagram, DHDL cannot confirm the bay functions and component scope.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-97b33315\">Consequently, the quotation may rely on assumptions.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-01c7163d\"><span class=\"ez-toc-section\" id=\"Providing_Voltage_but_Not_Fault_Level\"><\/span>Providing Voltage but Not Fault Level<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ce7ca3dd\">A 10kV system, for example, does not automatically determine the required breaking capacity.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e29f4975\">Therefore, provide the calculated fault current and required duration.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-7f448a6b\"><span class=\"ez-toc-section\" id=\"Selecting_a_Breaker_Brand_Without_Defining_Performance\"><\/span>Selecting a Breaker Brand Without Defining Performance<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-024260c2\">A brand name does not define current, breaking duty, control voltage, endurance, auxiliary contacts, or communication.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a84da0d8\">Instead, specify performance first and approved brands second.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-bfce5c64\"><span class=\"ez-toc-section\" id=\"Ignoring_Cable_Dimensions\"><\/span>Ignoring Cable Dimensions<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-19b64564\">Cable quantity and bending radius can affect the cabinet and civil design.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-be8b89a4\">Thus, provide cable data before approving the layout.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-80727caf\"><span class=\"ez-toc-section\" id=\"Treating_Five-Prevention_Interlocking_as_a_Marketing_Phrase\"><\/span>Treating Five-Prevention Interlocking as a Marketing Phrase<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b5d296a1\">The project team should verify the actual operating logic.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-03dc0fab\">Accordingly, review and approve the interlocking matrix.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-03430c7f\"><span class=\"ez-toc-section\" id=\"Leaving_Future_Expansion_Undefined\"><\/span>Leaving Future Expansion Undefined<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9e777ea4\">If the project may add panels, define the direction, busbar rating, interface, and reserved space.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-42d95144\">Otherwise, future expansion may require extensive shutdown or modification.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-7526e267\"><span class=\"ez-toc-section\" id=\"Assuming_Every_Document_Comes_Standard\"><\/span>Assuming Every Document Comes Standard<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-36cd94a5\">Some markets require specific drawings, certificates, languages, or inspection formats.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6dd271aa\">Therefore, attach a document schedule to the RFQ.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-ec433d92\"><span class=\"ez-toc-section\" id=\"Information_to_Send_for_a_KYN28_Quotation\"><\/span>Information to Send for a KYN28 Quotation<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7b7f8a58\">DHDL requests the system voltage, single-line diagram, rated current, short-circuit breaking capacity, main wiring scheme, cable entry and exit method, and project quantity.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3302ba8f\">For a more complete quotation, send the following information.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-20d87522\"><span class=\"ez-toc-section\" id=\"Required_Electrical_Information\"><\/span>Required Electrical Information<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>System voltage<\/li>\n\n\n\n<li>Highest voltage for equipment<\/li>\n\n\n\n<li>Frecuencia<\/li>\n\n\n\n<li>Earthing method<\/li>\n\n\n\n<li>Rated busbar current<\/li>\n\n\n\n<li>Rated current for each feeder<\/li>\n\n\n\n<li>Short-circuit current<\/li>\n\n\n\n<li>Short-circuit duration<\/li>\n\n\n\n<li>Breaking capacity<\/li>\n\n\n\n<li>Making capacity<\/li>\n\n\n\n<li>Insulation level<\/li>\n\n\n\n<li>Auxiliary AC voltage<\/li>\n\n\n\n<li>DC control voltage<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-49d2d02a\"><span class=\"ez-toc-section\" id=\"Required_Circuit_Information\"><\/span>Required Circuit Information<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Single-line diagram<\/li>\n\n\n\n<li>Main wiring scheme<\/li>\n\n\n\n<li>Incoming feeders<\/li>\n\n\n\n<li>Outgoing feeders<\/li>\n\n\n\n<li>Transformer feeders<\/li>\n\n\n\n<li>Motor feeders<\/li>\n\n\n\n<li>Bus coupler<\/li>\n\n\n\n<li>Metering panels<\/li>\n\n\n\n<li>Station service<\/li>\n\n\n\n<li>Future panels<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-14a34de2\"><span class=\"ez-toc-section\" id=\"Required_Component_Information\"><\/span>Required Component Information<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Circuit breaker type<\/li>\n\n\n\n<li>Preferred breaker brand, if applicable<\/li>\n\n\n\n<li>Protection relay functions<\/li>\n\n\n\n<li>Relay brand or approved list<\/li>\n\n\n\n<li>Current-transformer data<\/li>\n\n\n\n<li>Voltage-transformer data<\/li>\n\n\n\n<li>Metering requirements<\/li>\n\n\n\n<li>Surge arrester<\/li>\n\n\n\n<li>Communication protocol<\/li>\n\n\n\n<li>SCADA point list<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-ca24cfc5\"><span class=\"ez-toc-section\" id=\"Required_Installation_Information\"><\/span>Required Installation Information<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Indoor installation conditions<\/li>\n\n\n\n<li>Ambient temperature<\/li>\n\n\n\n<li>Altitude<\/li>\n\n\n\n<li>Humidity<\/li>\n\n\n\n<li>Dust<\/li>\n\n\n\n<li>Corrosion<\/li>\n\n\n\n<li>IP requirement<\/li>\n\n\n\n<li>Cable entry and exit<\/li>\n\n\n\n<li>Cable sizes<\/li>\n\n\n\n<li>Cable quantity<\/li>\n\n\n\n<li>Cable trench<\/li>\n\n\n\n<li>Switchgear room dimensions<\/li>\n\n\n\n<li>Future expansion direction<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-586a06e0\"><span class=\"ez-toc-section\" id=\"Required_Commercial_Information\"><\/span>Required Commercial Information<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Project country<\/li>\n\n\n\n<li>Cantidad<\/li>\n\n\n\n<li>Required delivery date<\/li>\n\n\n\n<li>Applicable standard<\/li>\n\n\n\n<li>Documentation language<\/li>\n\n\n\n<li>Inspection requirements<\/li>\n\n\n\n<li>Packing requirements<\/li>\n\n\n\n<li>Installation support<\/li>\n\n\n\n<li>Commissioning support<\/li>\n\n\n\n<li>Spare parts<\/li>\n\n\n\n<li>Warranty requirements<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d977c315\">If some data remains undecided, send the latest single-line diagram and load information. DHDL can then identify the missing technical decisions.<\/p>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-9155dde9\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Frequently Asked Questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-644744e9\"><span class=\"ez-toc-section\" id=\"What_voltage_range_does_DHDL_KYN28_switchgear_cover\"><\/span>What voltage range does DHDL KYN28 switchgear cover?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2d6bfffb\">DHDL specifies a voltage range of 3.6\u201312kV for three-phase AC medium-voltage power systems.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-70e314bd\"><span class=\"ez-toc-section\" id=\"What_does_KYN28_switchgear_do\"><\/span>What does KYN28 switchgear do?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e99645a4\">It receives, distributes, controls, protects, and monitors medium-voltage electrical power.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-00ad174f\"><span class=\"ez-toc-section\" id=\"Where_can_buyers_use_KYN28_switchgear\"><\/span>Where can buyers use KYN28 switchgear?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0ff0b8e9\">DHDL lists power plants, substations, industrial enterprises, infrastructure projects, commercial buildings, data centers, renewable energy projects, and medium-voltage power rooms.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-e12d1dfc\"><span class=\"ez-toc-section\" id=\"Why_does_KYN28_use_a_withdrawable_circuit_breaker\"><\/span>Why does KYN28 use a withdrawable circuit breaker?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c3df23ca\">The withdrawable breaker truck supports inspection, testing, maintenance, and replacement without complicated cabinet disassembly.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-10f83a7d\">However, operators must still follow the approved interlocking and safety procedures.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-deaa31d0\"><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_KYN28_and_an_RMU\"><\/span>What is the difference between KYN28 and an RMU?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b95bf7a6\">DHDL describes KYN28 as metal-clad withdrawable switchgear with a truck-type circuit breaker. In contrast, RMU and HXGN equipment provide more compact solutions mainly for ring-network and medium-to-small-capacity distribution projects.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-3d4e64a9\"><span class=\"ez-toc-section\" id=\"Does_KYN28_include_five-prevention_interlocking\"><\/span>Does KYN28 include five-prevention interlocking?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7a3f3a4d\">Yes. DHDL states that the product includes a complete five-prevention interlocking system to reduce incorrect operation and unsafe access risks.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-f52bc956\"><span class=\"ez-toc-section\" id=\"Can_DHDL_customize_KYN28_switchgear\"><\/span>Can DHDL customize KYN28 switchgear?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-933ce48b\">Yes. DHDL lists voltage, rated current, breaking capacity, circuit configuration, main wiring scheme, breaker type and brand, protection relay, cabinet layout, communication system, and applicable standards as customizable items.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-86b1bff0\"><span class=\"ez-toc-section\" id=\"Which_standards_does_the_product_follow\"><\/span>Which standards does the product follow?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-642cd18d\">DHDL states that KYN28 switchgear follows IEC 62271, GB\/T 3906, and other applicable international and domestic standards.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c8221ddf\">Nevertheless, buyers should confirm the exact edition, product scope, and required documentation.<\/p>\n\n\n\n<h3 class=\"wp-block-wd-title title wd-caadd3e4\"><span class=\"ez-toc-section\" id=\"What_information_does_DHDL_need_for_a_quotation\"><\/span>What information does DHDL need for a quotation?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-310439d8\">At minimum, provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>System voltage<\/li>\n\n\n\n<li>Single-line diagram<\/li>\n\n\n\n<li>Rated current<\/li>\n\n\n\n<li>Short-circuit breaking capacity<\/li>\n\n\n\n<li>Main wiring scheme<\/li>\n\n\n\n<li>Cable entry and exit method<\/li>\n\n\n\n<li>Cantidad<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-b6323965\"><span class=\"ez-toc-section\" id=\"Choose_KYN28_Around_the_Complete_Power_System\"><\/span>Choose KYN28 Around the Complete Power System<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-222e957b\">KYN28 switchgear should not be treated as a row of standard cabinets.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-845fd1b2\">Instead, the project team should select it around the complete power system:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li>Confirm the voltage and system earthing.<\/li>\n\n\n\n<li>Issue the single-line diagram.<\/li>\n\n\n\n<li>Define every panel function.<\/li>\n\n\n\n<li>Calculate the rated current.<\/li>\n\n\n\n<li>Confirm the short-circuit duty.<\/li>\n\n\n\n<li>Select the circuit breaker.<\/li>\n\n\n\n<li>Coordinate protection and metering.<\/li>\n\n\n\n<li>Define the interlocking logic.<\/li>\n\n\n\n<li>Provide cable data.<\/li>\n\n\n\n<li>Review the cabinet lineup.<\/li>\n\n\n\n<li>Plan future expansion.<\/li>\n\n\n\n<li>Approve the inspection and test plan.<\/li>\n\n\n\n<li>Close all technical deviations before production.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7d730666\">By following this process, buyers can reduce missing scope, protection mismatches, cable conflicts, unsafe operating logic, building modifications, and commissioning delays.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-28d3eec2\">Explore DHDL\u2019s broader <a href=\"https:\/\/dinghongtransformer.com\/es\/categoria-producto\/distribution-cabinets\/high-voltage-cabinet\/\"><strong><em><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">high-voltage cabinet range<\/mark><\/em><\/strong><\/a> if the project requires related medium-voltage equipment.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1223f137\">Then, when you are ready to request a technical proposal, send DHDL your single-line diagram, system voltage, rated currents, fault level, cable schedule, relay requirements, quantity, destination country, and project timetable.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b2502072\"><a href=\"https:\/\/dinghongtransformer.com\/es\/contactenos\/\"><strong><em><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Contact DHDL<\/mark><\/em><\/strong><\/a> to request a project-specific KYN28 metal-clad withdrawable switchgear solution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Learn how to select KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV systems, compare configurations, review safety features, and prepare an accurate RFQ.<\/p>","protected":false},"author":3,"featured_media":37966,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1,70],"tags":[103,107,128,112],"class_list":["post-37965","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-product-insights","tag-project","tag-dhdl","tag-kyn28-metal-clad-withdrawable-switchgear","tag-power-transformer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide - Dinghongtransformer<\/title>\n<meta name=\"description\" content=\"Learn how to select KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV systems, compare configurations, review safety features, and prepare an accurate RFQ.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide - Dinghongtransformer\" \/>\n<meta property=\"og:description\" content=\"Learn how to select KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV systems, compare configurations, review safety features, and prepare an accurate RFQ.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Dinghongtransformer\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-05T12:58:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-05T13:08:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/08\/image-24.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1344\" \/>\n\t<meta property=\"og:image:height\" content=\"898\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"wangying wangying\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"wangying wangying\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/\"},\"author\":{\"name\":\"wangying wangying\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/6b64551f21e33202848bdb5eda88b4fa\"},\"headline\":\"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide\",\"datePublished\":\"2026-08-05T12:58:47+00:00\",\"dateModified\":\"2026-08-05T13:08:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/\"},\"wordCount\":2975,\"image\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image-24.png\",\"keywords\":[\"#project\",\"DHDL\",\"KYN28 Metal-clad Withdrawable Switchgear\",\"power transformer\"],\"articleSection\":[\"Blog\",\"Product Insights\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/\",\"name\":\"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide - Dinghongtransformer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image-24.png\",\"datePublished\":\"2026-08-05T12:58:47+00:00\",\"dateModified\":\"2026-08-05T13:08:48+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/6b64551f21e33202848bdb5eda88b4fa\"},\"description\":\"Learn how to select KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV systems, compare configurations, review safety features, and prepare an accurate RFQ.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image-24.png\",\"contentUrl\":\"https:\\\/\\\/dinghongtransformer.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/image-24.png\",\"width\":1344,\"height\":898,\"caption\":\"KYN28 Metal-Clad Withdrawable Switchgear\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/blog\\\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/dinghongtransformer.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#website\",\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/\",\"name\":\"Dinghongtransformer\",\"description\":\"DHDL manufactures transformers, high and low voltage distribution cabinets, prefabricated substations, energy storage cabinets and EV charging equipment for utility, industrial and new energy projects worldwide.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dinghongtransformer.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dinghongtransformer.com\\\/#\\\/schema\\\/person\\\/6b64551f21e33202848bdb5eda88b4fa\",\"name\":\"wangying wangying\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e19cd3a1966b956f1730d88b74b4a12936cb95c434695061b738b7a1913ca47?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e19cd3a1966b956f1730d88b74b4a12936cb95c434695061b738b7a1913ca47?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6e19cd3a1966b956f1730d88b74b4a12936cb95c434695061b738b7a1913ca47?s=96&d=mm&r=g\",\"caption\":\"wangying wangying\"},\"url\":\"https:\\\/\\\/dinghongtransformer.com\\\/es\\\/author\\\/wangying\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide - Dinghongtransformer","description":"Learn how to select KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV systems, compare configurations, review safety features, and prepare an accurate RFQ.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/","og_locale":"es_ES","og_type":"article","og_title":"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide - Dinghongtransformer","og_description":"Learn how to select KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV systems, compare configurations, review safety features, and prepare an accurate RFQ.","og_url":"https:\/\/dinghongtransformer.com\/es\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/","og_site_name":"Dinghongtransformer","article_published_time":"2026-08-05T12:58:47+00:00","article_modified_time":"2026-08-05T13:08:48+00:00","og_image":[{"width":1344,"height":898,"url":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/08\/image-24.png","type":"image\/png"}],"author":"wangying wangying","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"wangying wangying","Tiempo de lectura":"14 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#article","isPartOf":{"@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/"},"author":{"name":"wangying wangying","@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/6b64551f21e33202848bdb5eda88b4fa"},"headline":"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide","datePublished":"2026-08-05T12:58:47+00:00","dateModified":"2026-08-05T13:08:48+00:00","mainEntityOfPage":{"@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/"},"wordCount":2975,"image":{"@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/08\/image-24.png","keywords":["#project","DHDL","KYN28 Metal-clad Withdrawable Switchgear","power transformer"],"articleSection":["Blog","Product Insights"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/","url":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/","name":"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide - Dinghongtransformer","isPartOf":{"@id":"https:\/\/dinghongtransformer.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#primaryimage"},"image":{"@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/08\/image-24.png","datePublished":"2026-08-05T12:58:47+00:00","dateModified":"2026-08-05T13:08:48+00:00","author":{"@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/6b64551f21e33202848bdb5eda88b4fa"},"description":"Learn how to select KYN28 metal-clad withdrawable switchgear for 3.6\u201312kV systems, compare configurations, review safety features, and prepare an accurate RFQ.","breadcrumb":{"@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#primaryimage","url":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/08\/image-24.png","contentUrl":"https:\/\/dinghongtransformer.com\/wp-content\/uploads\/2026\/08\/image-24.png","width":1344,"height":898,"caption":"KYN28 Metal-Clad Withdrawable Switchgear"},{"@type":"BreadcrumbList","@id":"https:\/\/dinghongtransformer.com\/blog\/kyn28-metal-clad-withdrawable-switchgear-buyers-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/dinghongtransformer.com\/"},{"@type":"ListItem","position":2,"name":"KYN28 Metal-Clad Withdrawable Switchgear: A Practical Buyer\u2019s Guide"}]},{"@type":"WebSite","@id":"https:\/\/dinghongtransformer.com\/#website","url":"https:\/\/dinghongtransformer.com\/","name":"Dinghongtransformer","description":"DHDL fabrica transformadores, armarios de distribuci\u00f3n de alta y baja tensi\u00f3n, subestaciones prefabricadas, armarios de almacenamiento de energ\u00eda y equipos de carga para veh\u00edculos el\u00e9ctricos para proyectos de servicios p\u00fablicos, industriales y de nuevas energ\u00edas en todo el mundo.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dinghongtransformer.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/dinghongtransformer.com\/#\/schema\/person\/6b64551f21e33202848bdb5eda88b4fa","name":"wangying wangying","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/6e19cd3a1966b956f1730d88b74b4a12936cb95c434695061b738b7a1913ca47?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6e19cd3a1966b956f1730d88b74b4a12936cb95c434695061b738b7a1913ca47?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6e19cd3a1966b956f1730d88b74b4a12936cb95c434695061b738b7a1913ca47?s=96&d=mm&r=g","caption":"wangying wangying"},"url":"https:\/\/dinghongtransformer.com\/es\/author\/wangying\/"}]}},"_links":{"self":[{"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/posts\/37965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/comments?post=37965"}],"version-history":[{"count":2,"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/posts\/37965\/revisions"}],"predecessor-version":[{"id":37968,"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/posts\/37965\/revisions\/37968"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/media\/37966"}],"wp:attachment":[{"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/media?parent=37965"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/categories?post=37965"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dinghongtransformer.com\/es\/wp-json\/wp\/v2\/tags?post=37965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}